LatPile

價格:免費

更新日期:2016-09-22

檔案大小:840.7 KB

目前版本:3.0

版本需求:需要 iOS 10.0 或以上版本。與 iPhone、iPad 及 iPod touch 相容。

支援語言:英語

LatPile(圖1)-速報App

LatPile calculates the maximum allowable lateral load applied to a vertical steel pipe pile in marine environment. The pile is treated as a cantilever pile. The calculations assume that the point of fixity is 5D below the mud line, where D is the outer diameter of the pile. Users need to confirm that the underlining assumptions are appropriate for the target geotechnical environment.

Users need to specify water depth, elevation of load above water line, factor of safety, yield strength, pile diameter and wall thickness. Most commonly used piles with diameter in the range of 6 in. to 60 in. are coded in the pile table for user selection. The corresponding commonly used wall thickness are coded in a separate table for user selection. In addition to the maximum allowable lateral load, the app also output the pile stiffness, the corresponding bending moment and deflection.

LatPile(圖2)-速報App

LatPile(圖3)-速報App

LatPile(圖4)-速報App

支援平台:iPhone